get_last_versions(active=True) returns nothing when the newest version is inactive — next publish restarts at v001 #384
get_last_versions(..., active=True) (the default) returns nothing for a product whose newest version is inactive, even when older active versions exist. Publishing then restarts at version 1, and the core integrator updates the existing v001 instead of creating a new version.
Where
ayon_api/_api_helpers/versions.py (checked on develop at 4b248d4): with latest=True the query sends latestOnly: true to the server, and the active filter is applied afterwards, on the client:
Publish again: ayon-core's CollectAnatomyInstanceData finds no last version and uses the versioning start (1); IntegrateAsset finds the existing v001 and updates it in place: its representations/files are replaced by the new publish (and on a shared storage the v001 files would be overwritten).
Expected
The latest active version (v005), so the next publish is v006 (but never v001).
Environment
AYON server 1.17.3, ayon-core 1.9.12, AYON launcher 1.6.3 (Python 3.11.9), Windows client. Same code on ayon-python-api develop4b248d4.
Possible fix
When latest and active are both set, either filter by active on the server side before "latest" is applied, or (if the server can't) query without latestOnly and pick the highest version per product among the matching ones on the client.