Simulink/Simscape study of solid-state transformer (SST) architectures built from modules, where a module is a galvanically isolated DC-DC converter followed by a single-phase inverter: modules are paralleled on the DC side and their inverters are series-connected on the AC side. The repository holds the two-module SST bench (two CLLC DC transformers of the library feeding two three-level T-type single-phase inverters in series on the line), the bench of the isolated stage alone as a CLLC DC transformer (DCX, 800 V / 800 V, 50 kW, 50 kHz, SiC, with a 35 kHz variant at 790 V / 700 V) and first-cut sizing scripts for the medium-frequency transformers. The single-phase DAB variant of the SST bench was removed on 2026-10-24 (still in the git history).
Earlier variants with two-level and NPC inverters and with a three-phase DAB were removed
from the tree in March 2026 (still in the git history); the three-phase DAB study lives in
advanced-dcdc-converters.
Simulation results are discussed in the solid_state_transformers document published on
the organization page (pwr-control/docs/solid_state_transformers).
- MATLAB with Simulink, Simscape and Simscape Electrical.
- The companion library repository on the MATLAB
path with subfolders (every
init_model.mof this repository does it by itself through itsprivate/library_setup.m, cloning the library next to this repository when it is missing): the CLLC-DCX blockcllc_dcx/cllc_dcx_mod1(Simscape-language power stagecllc_ssc, to be built once withssc_build cllc_sscfromlibrary/foundation/pwr_electronics), masked power stages (three-level T-type inverter with thermal model, three-level PWM modulator with global TRGO, DC link, lithium-ion battery, single-phase transformer,mos_simple_2th), thedq_vector_picontrol block, and the setup classes and functions used byinit_model.m(init_environment,timing_setup,hw_single_phase_inverter_setup,ctrl_single_phase_inverter_setup,hw_cllc_single_phase_setup,ctrl_cllc_setup,device_mosfet_setup,lithium_ion_battery_setup,cllc_dcx_param_example, ...).
- Run
init_model.min the project folder: it builds theparamstructure (one group per subsystem:param.sim,.time,.glb_time,.cllc,.spinv,.grid,.battery,.thermal, ...; the numbers of the bench are inprivate/*_param.m, those of the DCX incllc_dcx_param_example.mof the library), prints the operating point and opens the model. The SST bench runs 1.25 s with the inverters at 4 kHz (double update) and the DCX at 50 kHz, 2 × 50 kW, two 800 V packs,wolfspeed_SiC_MOSFET_CAB006M12GM3with thermal model (itsinit_model.mholds the simulation settings only, the rest is built inprivate/); the CLLC-DCX benches run 0.25 s with the last 50 ms logged. All of them use the Simscape Backward Euler local solver with the fixed stepparam.sim.tc(1 µs in the SST bench, 50 to 500 ns in the DCX benches: the method damps the resonant tank in proportion to tc, see the READMEs). - Simulate the
.slx. In the SST bench, the first time, runupdate_sst_cllc_ttype_inv.mbefore simulating (it fixes the model around the library DCX blocks and saves it). - Post-process with
power_loss_calculus.m,plotting_results.mandspectrum.m; figures go tofigures/(EPS, ignored by git).
Each converter runs on its own local time base (time_master, time_afe_module_A/B,
time_cllc_module_A/B in the SST model, the local clock of the DCX block): the modulators
generate the control triggers, and the local clocks can be detuned to study the effect of time
sliding between modules.
| Folder | Content |
|---|---|
theory_analysis_solid_state_transformer |
The two-module SST bench (CLLC-DCX + T-type inverters), the CLLC-DCX benches of the isolated stage (800 V / 800 V at 50 kHz, and a 35 kHz variant at 790 V / 700 V) and the transformer sizing scripts |
The folder has its own README with the project descriptions.