feat: noise relative to the sample's own spread with RandomGaussianNoiseGPU(relative=True) - #147

Open
Hendrik-code wants to merge 1 commit into
mainfrom
hm/gaussian-noise-relative
Open

Hendrik-code wants to merge 1 commit into
mainfrom
hm/gaussian-noise-relative

Conversation

@Hendrik-code

Copy link
Copy Markdown
Collaborator

What

RandomGaussianNoiseGPU takes relative (default False). When set, std is read as a fraction of each sample's own std in that channel, not in absolute intensity units:

"RandomGaussianNoiseGPU": { "p": 0.1, "std": 0.2, "relative": true }

Why

The std is drawn from U(0, std) in absolute units, so one config is a different augmentation on every intensity scale. Measured on 128³ training patches, image std is about 0.9 on z-scored Dixon MR, 0.17 on CT under nnU-Net's CT normalisation, and 0.16-0.20 on a [0, 1] SynthSeg synthesis. The paper config's std: 1.0 therefore means:

  • noise up to about the image's own spread on MR;
  • up to about six times it on CT and on synthetic samples.

For scale, nnU-Net's default noise std is at most 0.1 on z-scored data (from memory of batchgenerators' noise_variance=(0, 0.1), which it uses as the std).

Behaviour

  • The relative scale is applied after both random draws, so the noise field is the absolute one rescaled per sample (tested). mean stays absolute.
  • The absolute path is arithmetically unchanged: the batch-shared std now broadcasts through the same reshape as the per-sample one, which multiplies by the same value (tested bit-exact against the old formula).
  • Also fixes the docstring, which gave the default std as 0.1. It is 1.0.

Tests

unit_tests/test_gaussian_noise_relative.py:

  • the absolute form is bit-identical to the old arithmetic;
  • the relative form is scale-equivariant;
  • it equals the absolute draw × the sample std;
  • the registry accepts the key.

Full suite: 477 passed, 13 skipped. mypy smauglab/ clean, pre-commit passes.

🤖 Generated with Claude Code

…iseGPU(relative=True)

The noise std is drawn from U(0, std) in absolute intensity units, so one
config is a different augmentation on every intensity scale. With the paper
config's std 1.0 a z-scored MR patch (std ~0.9) gets noise up to about its
own spread, a CT patch under nnU-Net's CT normalisation (std ~0.17) up to six
times its spread, and a [0, 1] SynthSeg synthesis (std ~0.18) likewise.

`relative=True` reads `std` as a fraction of each sample's std in that
channel, which makes the transform scale-equivariant. The scale is applied
after both random draws, so the noise field is the absolute one rescaled per
sample. `mean` stays absolute. Default False; the absolute path is
arithmetically unchanged (the per-sample and batch stds now broadcast through
the same reshape, which multiplies by the same value).

Also corrects the docstring, which gave the default std as 0.1; it is 1.0.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@Hendrik-code

Copy link
Copy Markdown
Collaborator Author

Results: Dataset803 and Dataset804, fold 0

Relative noise with a cap of 0.2 sample stds is equivalent to the paper config on Dataset803. On Dataset804 out-of-domain it is slightly worse, mostly in the Dixon water cohort. The arm changes two things at once: the noise becomes scale-free, and it becomes much weaker on CT. So the result argues against weakening the noise, not against making it relative.

Setup. nnUNetTrainerDAExtGPU, 3d_fullres, fold 0, 1000 epochs, one run per arm. Dataset803 is trained on SpineGAN Dixon in-phase MRI and Dataset804 on SpineGAN CT; out-of-domain is every other modality and sequence in the test split (803: 1077 scans out, 24 in; 804: 462 out, 639 in). Metric is global binary Dice, averaged over vertebra, IVD and spinal canal per scan. Verdicts are TOST equivalence at ±0.01 (α = 0.05) on paired per-scan deltas. For scale, three fold-0 runs of the paper config span 0.0043 (803) and 0.0079 (804) out-of-domain in cohort means.

arm config code GPU
relative 0.2 paper config with RandomGaussianNoiseGPU: "std": 0.2, "relative": true (p stays 0.1) 2918d1e (this branch) L40S
paper (replicate) transform_params_one-sequence-to-segment-them-all.json 7169464 A40
paper (published run) same b0110743 A40

Relative 0.2 minus paper (replicate), paired mean and 95% CI:

in-domain out-of-domain
Dataset803 +0.001 [+0.000, +0.002] −0.007 [−0.008, −0.006]
Dataset804 +0.000 [−0.000, +0.000] −0.010 [−0.011, −0.008]

Three of the four cells are equivalent (TOST p < 0.001). On Dataset804 out-of-domain the point estimate is inside the margin but the interval is not bounded by it (TOST p = 0.44). Against the published run, the four deltas are +0.001, −0.006, +0.000 and −0.007, all equivalent.

Cohort means: 803 in / out 0.902 / 0.841 (paper replicate 0.901 / 0.844). 804 in / out 0.903 / 0.766 (paper replicate 0.903 / 0.781, so −0.016 out-of-domain).

Where it moves, per cohort against the replicate:

  • Dataset803: myelom-ct −0.012 [−0.013, −0.011] and spinegan-ct −0.008. The MRI cohorts are within ±0.002.
  • Dataset804: Dixon water −0.044 [−0.063, −0.025], with 6 of 24 scans down by more than 0.05. Dixon in-phase −0.013, spider-T2w −0.010, spider-T1w −0.005. The CT cohorts are unchanged.

The loss lands on the other modality in both datasets: CT for the MRI-trained model, MRI for the CT-trained one. On CT patches (std about 0.17), the paper's absolute cap of 1.0 is about 6 sample stds; this arm's cap is 0.2 stds, about 30 times weaker. On z-scored MRI (std about 0.9) it is about 5 times weaker. This fits the heavy CT noise acting as a useful appearance augmentation rather than a defect.

Caveat: GPU model. This arm's Dataset804 run trained on an L40S; every reference trained on an A40. On Dataset804 Dixon water, the three arms of this round that trained on the L40S (#147, #149, #150) scored 0.724, 0.698 and 0.539. That is below all 23 other full-capacity arms on 804 (0.756 to 0.778) and all four runs of the paper config (0.767 to 0.771). An earlier paper-family run on the same L40S scored 0.759, with no scan more than 0.05 below the paper config, so the card alone does not produce the drop. With one run per cell, an interaction between card and arm is not excluded; an A40 rerun on 804 would settle it.

In training. About 36 s/epoch on the L40S, no non-finite losses in either run. At p = 0.1 the noise fired in 1 of 20 pre-flight batches, so the dose check forced p = 1 on both sides.

Bottom line: the option defaults to off and is safe to merge. The result does not justify replacing the paper's absolute noise. To test scale-free noise on its own, the relative cap would need to match the old dose on CT, about 1 to 6 sample stds.