Documents read-only CLI access on the LEOX LXT-010S-H with firmware V3.3.4L7, where the telnet service accepts the connection on port 23 but closes it immediately (no banner, no login) and the web UI "Remote Access Configuration" page renders empty.

The stick still exposes the Realtek Boa formSysCmd handler (command injection, CVE-2019-19824 family), which allows omcicli/diag commands with the documented leox account — enough for a full read-only OMCI dump without telnet or UART.

Also adds a warning that formExportOMCIlog hangs the single-threaded Boa server and leaves verbose OMCI logging enabled (omcicli set logfile 3 ffffffff), requiring a physical power cycle to recover.