Skip to content

Writing Value for EMS_EP_RESERVE #68

Open

Description

@hismastersvoice

I tried to write the value for Emergency-Power-Reserve via RSCP to my E3DC
Reading the value works fine.

But if I try to write, I always get NULL back and the value don't change.
Can anybody help me please? Thanks in advance.

I have found that this value is % of the installed batterie capacity, and it is given als float32 eg 25.00 etc.

def set_epr(self, ep_reserve=None, keepAlive=False):

    res = self.sendRequest(
        (
            "EMS_REQ_EP_RESERVE",
            "Container",
            [
                ("EMS_EP_RESERVE", "Float32", ep_reserve),
            ],
        ),
        keepAlive=keepAlive,
    )

Activity

  1. Selaron commented on Oct 16, 2022

    @Selaron

    After several attempts I did it like that and it worked, setting EP Reserve to 1650 Wh:

    from e3dc import E3DC
    
    ...
    
    retval = e3dc.rscp.sendRequest(
            (
                "SE_REQ_SET_EP_RESERVE",
                "Container",
                [
                    ("SE_PARAM_INDEX", "Uint32", 0),
                    ("SE_PARAM_EP_RESERVE", "Float32", 0.0),
                    ("SE_PARAM_EP_RESERVE_W", "Float32", 1650.0),
                ],
            )
        );
    
    

    Idea borrowed from here: https://github.com/nischram/E3dcGui/blob/1ed3dc163287f7227b303e22d4ff20c650143ad0/Rscp/RscpSet.cpp#L105

  2. hismastersvoice commented on Oct 20, 2022

    @hismastersvoice
    Author

    You are my hero ;)
    Work well.

    Thanks.

  3. Selaron commented on Oct 21, 2022

    @Selaron

    Only thing is that for some reason the new value does not update on the touch screen UI, but it actually works.

  4. hismastersvoice commented on Oct 21, 2022

    @hismastersvoice
    Author

    @Selaron

    I can confirm this.
    The display stays with the old value.

    Also reading the set value was a bit difficult.
    You only get a % value, but this % is calculated by installed capacity and state of health of the batteries.

    For me it work perfectly now.

  5. Selaron commented on Oct 21, 2022

    @Selaron

    Using this you can get the Wh reserve setting:

    retval = e3dc.rscp.sendRequest(
                    ("SE_REQ_EP_RESERVE", "None", None),
        )[2][2][2];
    
    

    The [2][2][2] extracts the value out of the tuple.