5 changes: 3 additions & 2 deletions docs/core/diagnostics/eventpipe.md
Original file line number Diff line number Diff line change
Expand Up @@ -72,10 +72,11 @@ However, you can use the following environment variables to set up an EventPipe

* `COMPlus_EventPipeOutputPath`: The path to the output EventPipe trace file when it's configured to run via `COMPlus_EnableEventPipe`. The default value is `trace.nettrace`, which will be created in the same directory that the app is running from.

* `COMPlus_CircularBufferMB`: The size of the internal buffer that is used by EventPipe when it's configured to run via `COMPlus_EnableEventPipe`.
* `COMPlus_EventPipeCircularMB`: A hexadecimal value that represents the size of EventPipe's internal buffer in megabytes. This configuration value is only used when EventPipe is configured to run via `COMPlus_EnableEventPipe`. The default buffer size is 1024MB which translates to this environment variable being set to `400`, since `0x400` == `1024`.

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Do we want to describe what happens when the value is too low or too high?

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

That's still on my todo list. I figured I should do that in one PR that changes both this one and the dotnet-trace doc since the same issues will happen if values are too low/high.

* `COMPlus_EventPipeConfig`: Sets up the EventPipe session configuration when starting an EventPipe session with `COMPlus_EnableEventPipe`.
* `COMPlus_EventPipeProcNumbers`: Set this to `1` to enable capturing processor numbers in EventPipe event headers. The default value is `0`.

* `COMPlus_EventPipeConfig`: Sets up the EventPipe session configuration when starting an EventPipe session with `COMPlus_EnableEventPipe`.
The syntax is as follows:

`<provider>:<keyword>:<level>`