Invalid parquet writer options (e.g. max_row_group_size = 0, bloom_filter_fpp = 1.5) panic in COPY instead of returning an error #24904
ParquetOptions::into_writer_properties_builder (datafusion/common/src/file_options/parquet_writer.rs) passes the session options straight to the parquet crate's WriterPropertiesBuilder. Several of its setters assert! on values they cannot accept, so an invalid SET turns the next parquet write into a panic (or a hang) instead of a configuration error.
To Reproduce
SETdatafusion.execution.parquet.max_row_group_size=0;
COPY (SELECT1) TO 'x.parquet';
thread 'main' panicked at parquet-59.2.0/src/file/properties.rs:756:9:
assertion `left != right` failed: Cannot have a 0 max row group row count
SETdatafusion.execution.parquet.bloom_filter_fpp=1.5; -- also 0, 1, -1, NaN
COPY (SELECT1) TO 'x.parquet';
thread 'main' panicked at parquet-59.2.0/src/file/properties.rs:1665:13:
bloom filter fpp must be between 0 and 1 (exclusive) ...
SETdatafusion.execution.parquet.write_batch_size=0;
COPY (SELECT1) TO 'x.parquet'; -- never returns
The same applies to column_index_truncate_length = 0, statistics_truncate_length = 0, a per-column bloom_filter_fpp, and content_defined_chunking.min_chunk_size = 0 / max_chunk_size <= min_chunk_size.
Expected behavior
A configuration error naming the option, like the existing handling of an unknown compression or encoding string in the same function.
Additional context
Found while running a corpus of extreme configuration values against a debug build of datafusion-cli.
Activity
tripleaceme commentedon Oct 18, 2026
take
fix: reject invalid parquet writer options when they are set
tripleaceme commentedon Oct 21, 2026
untake