ReoNvr is a self-hosted recording archive for Reolink cameras. It records native RTSP streams, recovers missed footage from camera storage when available, and provides a browser interface for cameras, detections, and local playback. It does not transcode video or change camera recording schedules, streaming settings, detection rules, storage, or time settings. It never deletes camera SD-card media.

Requirements

  • Docker Engine with Docker Compose v2 on Linux, or Docker Desktop running Linux containers on Windows/macOS.

  • A Linux amd64 or arm64 Docker server. Intel/AMD PCs normally use amd64; Apple Silicon and ARM64 Linux devices use arm64. Check with:

    docker info --format '{{.Architecture}}'
  • A reachable Reolink camera with an account allowed to read device information, events, recordings, and RTSP streams. Enable the required camera services in the Reolink application yourself if they are unavailable.

  • Enough disk space for the archive and a browser capable of decoding the selected native camera codec. HEVC/H.265 playback depends on the browser and operating system; selecting an available H.264 sub-stream can improve compatibility without transcoding.

License

ReoNvr is free for an individual's personal, noncommercial use under the custom license. Copies, forks, redistributions, and projects using copied code must credit Jebarson Jebamony (@Jebarson) and preserve the license. Commercial use and use by or on behalf of companies or other organizations are prohibited, even if distributed or provided free of charge. Attribution does not permit commercial or company use. This is source-available, not open-source. Third-party dependencies and bundled Reolink tools retain their own licenses and EULA obligations.

Download and Install

  1. Open Releases and download the ZIP for your Docker server architecture, for example ReoNvr-v1.0.2-linux-amd64.zip or ReoNvr-v1.0.2-linux-arm64.zip. Version v1.0.2 is the initial public release. Downloads from this public repository need no GitHub account. Running the ZIP needs no source checkout, compiler, or registry credentials. Read the accompanying license before use.

  2. Verify the downloaded ZIP against its accompanying .sha256 file and extract it into a dedicated folder. The ZIP contains all three Docker images, Compose configuration, startup scripts, checksums, version metadata, and required third-party licenses. This README, guides, and screenshots remain in the repository and are not included in the ZIP.

  3. Optionally edit the extracted .env before first startup. Keep REONVR_VERSION and REONVR_ARCH unchanged. The defaults use Docker-managed persistent volumes and expose the web interface only on this computer.

  4. Start Docker, then run the appropriate script from the extracted folder.

    Windows PowerShell:

    powershell.exe -NoProfile -ExecutionPolicy Bypass -File .\start.ps1

    Run this only after verifying and extracting the ZIP. The execution-policy override applies to this process, not your machine-wide settings. Organization policies may still require administrator approval.

    Linux/macOS shell:

    sh ./start.sh

    The scripts require complete checksum coverage of all seven immutable assets, check the Docker architecture, and compare every Compose image (including optional profiles) with the checked image manifest before importing or starting anything. They then wait for application and gateway health checks. The editable .env is intentionally excluded from the internal checksums.

  5. Open http://localhost:8080, or the HTTP port configured in .env.

After the ZIP is downloaded, installation does not pull images or install dependencies from the internet. Camera access still requires connectivity from Docker to your camera network. The gateway is private to the Compose network.

First Camera

Fresh installations have Recording enabled by default. Set it to Paused before adding cameras if you want to control when capture begins; saving an enabled camera with archiving selected can otherwise start recording immediately. Pausing ingestion does not pause automatic archive retention, described below.

The screenshots below use illustrative demo data. Camera addresses, credentials, and camera images are covered with solid privacy masks.

Camera list with recording paused and camera addresses masked

Detect Automatically

  1. Open Cameras and choose Detect Automatically. ReoNvr scans for reachable Reolink devices and lists them under Detected cameras.
  2. Choose Add camera beside the device you want. Its name, address, and native port are filled in for you. Devices already registered show Already added.
  3. Enter the camera credentials, select the stream, and choose Test connection. Review its capabilities and recording options, then save it as described below.

Automatic detection results with camera addresses masked

Detection does not add cameras, supply credentials, or enable recording by itself. It does not change camera settings. If a device is not found, add its address manually instead.

For Docker hosts with suitable LAN networking, enable the optional discovery relay by adding this setting to the extracted release's .env:

COMPOSE_PROFILES=discovery

Run the normal startup script. Keep this setting when transferring your configuration to a new release so upgrades also recreate the relay with its new image.

The relay uses host networking and UDP 2000; native replies require host UDP 3000. Leave REONVR_DISCOVERY_PORT=3000 for automatic detection. Alternate host port mappings require manual camera registration. Camera discovery needs broadcast reachability and may not cross subnets, VPNs, or Docker Desktop's Linux VM. Use manual registration when it cannot reach the camera LAN. ReoNvr does not change Docker Desktop, firewall, or camera configuration automatically.

Only one installation can own host UDP 2000 and 3000 at a time. Before moving discovery to another installation, stop the old installation's app and discovery relay; do not delete its volumes. Using different HTTP ports does not resolve these UDP conflicts.

Add Manually and Configure Recording

  1. Open Cameras, choose Add camera, and enter its name, LAN address, and camera credentials. Skip entering the address if you selected a detected device. There are no default camera credentials.
  2. Select the stream quality and choose Test connection. ReoNvr reads the model, clock information, streams, events, and storage/search capabilities. Changing stream quality requires another connection test.
  3. Select Events to retain footage around selected detections, or Continuous to keep every stream-copy segment. Optionally enable Recover missed recordings from camera storage when the connection test confirms usable camera storage and recording search.
  4. Save the camera. In Settings, select the archive subfolder and folder layout. The archive subfolder is relative to /archive.
  5. If you paused recording during setup, enable the application-wide Recording switch when capture should run. Disable it to pause ingestion across all cameras.

Camera connection and recording options with address, credentials, and preview image masked

Recovery fills monitored missing intervals, not the camera's entire history. It can only recover footage the camera actually recorded and still retains. Keep camera and host clocks synchronized yourself. Playback shows locally verified archived media, not camera-only search results. A discovered event is not proof that its video has been archived.

Clock differences and unavailable daylight-saving rules produce a warning, not a registration or recovery block. Failed probes retain a usable last-known clock. Without one, ReoNvr uses the camera's readable current time and reported offset for a best-effort clock, falling back to UTC when neither is available. Historical timestamps can be approximate, especially across a DST change; re-test the camera after correcting its clock or changing DST settings. Estimated-clock recovery remains provisional: downloads are still available, but their coverage cannot close missing intervals until reliable clock rules allow timestamp revalidation. Affected intervals are rescanned after the clock is verified; ambiguous timestamps remain provisional.

Automatic Event Detection

ReoNvr reads the camera's native detections, such as Motion, Person, Vehicle, and Animal, according to that model's capabilities. It does not run a separate AI detector or change the camera's detection rules. Select the event types you want while configuring the camera. With recording enabled, Events mode retains footage around those detections; Continuous mode retains all footage. Use Playback and its event-type filters to find local video for those detections. Enable the desired detection features in the Reolink application yourself if the camera is not reporting them.

Configuration

Edit .env, then rerun the appropriate startup script above so checksum and image checks still run. Keep REONVR_VERSION and REONVR_ARCH from the new ZIP; inherited shell environment values override .env and stale values are rejected.

Setting Default Purpose
REONVR_HTTP_PORT 8080 Host web port
REONVR_BIND_ADDRESS 127.0.0.1 Host interface exposing the web UI
REONVR_DISCOVERY_PORT 3000 Keep 3000 for automatic detection; alternate ports are manual-registration only
REONVR_RECORDINGS_PATH Docker volume Optional absolute host archive directory
COMPOSE_PROJECT_NAME reonvr-release Persistent release installation identity, separate from the source checkout
COMPOSE_PROFILES Not set Set discovery to persist the optional relay across startups and upgrades

To store recordings in a host folder, set REONVR_RECORDINGS_PATH to an existing absolute path such as /srv/reonvr/recordings or D:/ReoNvr/recordings. On Linux, the container user (UID/GID 10001) needs write access. ReoNvr does not change host folder ownership automatically. Changing this mount does not move existing recordings; preserve the old archive and plan a deliberate migration.

Automatic Retention

There is no configurable retention-period setting. When free archive capacity drops below a calculated reserve for 30 minutes of enabled cameras' selected streams, ReoNvr automatically deletes the oldest completed local recordings and their metadata until the reserve is restored. Active and partial recordings are protected. Retention continues while the Recording switch is paused. Stop the stack before making a consistent backup or freezing archive changes. Retention never deletes camera SD-card media.

Do not expose ReoNvr directly to the internet. The application does not supply an internet-facing authentication/TLS boundary. Keep loopback binding, or use a trusted network and an authenticated HTTPS reverse proxy. Camera credentials are encrypted at rest, but that does not make an exposed web interface safe.

Operation and Backups

Run these commands from the extracted release folder:

docker compose ps
docker compose logs --tail=100 app gateway
docker compose stop
docker compose start

Docker-managed volumes persist the database, encryption key, gateway state, and archive across container recreation. Keep the same COMPOSE_PROJECT_NAME across upgrades. Never run docker compose down -v on an installation you want to keep: it deletes named volumes, including the encryption key and recordings.

Before a backup, pause recording in the UI and stop the stack. Back up .env and the data, secrets, gateway, and archive volumes together, or the configured host archive folder instead of the archive volume. docker compose config --volumes lists the named volumes. Store backups securely: database and key backups together can decrypt saved camera credentials. Losing the master key makes saved credentials unusable. Start the stack again when the backup finishes.

Upgrading

  1. Read the new release notes, pause recording, stop the old stack, and take a consistent backup of its configuration, data, key, and archive.
  2. Extract the new matching-architecture ZIP into a new folder. Transfer your customized settings from the previous .env, but retain the new REONVR_VERSION and REONVR_ARCH. Keep the old project name and archive path.
  3. Run the new startup script, check docker compose ps, and verify cameras, recordings, playback, and recording controls before resuming ingestion.

Database migrations run automatically. Do not start an older image against a newer database unless its release notes explicitly allow it. Rollback may require restoring the matching database, key, configuration, and archive backup. Source-checkout deployments use a different bind-mount layout: do not replace their Compose file with the release file without migrating their data first. Older release ZIPs used reonvr; preserve that explicit project name when upgrading them, even though new installations now default to reonvr-release. Changing it creates different named volumes rather than moving your data.

Migrating a Source Deployment

Stop the source stack and take a consistent backup before the first release startup. Migrate runtime/data, runtime/secrets, and runtime/gateway together into the release's corresponding named volumes, preserving the database and its matching master key. Migrate runtime/archive into the archive volume, or retain the existing archive with an absolute REONVR_RECORDINGS_PATH. Preserve file permissions required by UID/GID 10001 and verify every mounted path before starting. The startup scripts do not migrate or discover source-checkout data. Keep the source backup intact until cameras and archived playback are verified. For an independent fresh install, leave the new project name unchanged and choose unused HTTP and discovery ports before starting alongside another deployment.

Troubleshooting

  • A port is already in use: choose an unused HTTP port in .env. Automatic detection requires host UDP 3000; choosing another discovery port means using manual registration instead.
  • Camera connection fails: verify Docker-to-camera routing, credentials, permissions, and required native/RTSP services without exposing them online.
  • HEVC does not play: verify operating-system/browser HEVC support or choose an available H.264 stream. ReoNvr preserves native codecs.
  • Archive is not writable: check free space and UID/GID 10001 access to a custom host mount. Do not change ownership recursively on unrelated data.
  • Recovery remains incomplete: inspect camera recovery intervals and camera storage availability. Missing or corrupt footage is not marked recovered.
  • Startup fails: use docker compose ps and the bounded logs command above. Redact credentials, authenticated URLs, addresses, and recordings before sharing diagnostic output.
  • Checksums or image selection fail: do not bypass the startup script or regenerate the manifest. Extract a fresh matching-architecture ZIP, retain its version and architecture settings, and clear stale overrides in your shell.

Contributing

See the development and contribution guide for the Docker development setup, colocated test layout, CI, versioned releases, and review policy.