I think for diagnostics, it is probably ok to make the following assumptions for now since we've decided these are independent of TCBs configured for filewriter etc:
TCBs for all spectra are the same (this ensures we can get a 3D histogram with time bin N referring to the same time-range for every spectrum)
Linear time binning, so the parameters a user can adjust are start, stop and number of bins.
This should give enough flexibility for visual diagnostics and the common scripting workflows where people would use this diagnostic data. We can still support more complicated diagnostic TCBs later if that turns out to be needed.
(This just applies to kafka_dae_diagnostics - we may still need spectrum-specific TCBs for filewriter etc).
Activity
Tom-Willemsen commentedon Aug 26, 2026
I think for diagnostics, it is probably ok to make the following assumptions for now since we've decided these are independent of TCBs configured for filewriter etc:
This should give enough flexibility for visual diagnostics and the common scripting workflows where people would use this diagnostic data. We can still support more complicated diagnostic TCBs later if that turns out to be needed.
(This just applies to
kafka_dae_diagnostics- we may still need spectrum-specific TCBs for filewriter etc).